ATS ( automatic transfer switch )





PLN Off? Operate the Automatic Generator!What is Ats Amf?ATS is an abbreviation of AutomaticTransfer Switch, which is the process of moving from the feeders feeders / power source of one into another power source alternately appropriate programming orders, ATS is the development of COS or commonly referred to expressly as Change Over Switch, both are located on different system works, for the ATS control work is done automatically, while the COS is controlled or operated manually.AMF stands for in terms of electricity from Automatic Main Failure is meant to explain how the automation of the system to a backup electrical system in case of interference with the source / main power feeders (Main), this term in general is often described as a system control start and stop generators, eitherthe diesel generators, gas generators and turbines.
System ATS and AMF panels work we often find is a good combination for the exchange of resources from the generator to the pln and vice versa, when a current source of electricity suddenly goes out, then the AMF tasked to run the diesel generators as well as providing protection against generator system, either protection against engine unit / engine in the form of security against disruption of low lube oil pressure (Low Oil Pressure) machine and temperature conditions as well as the cooling medium, and also provide protection to the generator unit. either in the form of security against excess usage charges as well as protection against other karakterlistrik such as voltage or frequency generator, if the parameter exceeds the secured batasannormal / ATS task is setting then disconnect the electrical current to the load while the AMF duty to dismiss the work machine.If the generator is operating properly executed, the next ATS charge transfer from the previous connection is connected with the pln transferred automatically to the side of the generator so that electricity can be connected to the user side.If then pln return to normal, then ATS duty to restore its path by moving the switch back to the primary side and then followed with AMF duty to dismiss the diesel engine work, and so on all the control systems are controlled automatically run by itself.Use of this automation system has several advantages, among others:1. Transfer system of the generator and vice versa pln need only a very short time, only a matter of seconds just after pln outage, electric generators direct and immediate start can be in 'enjoy' returned by the user.2. Lighten the electrical technician job can be very much at all, even office buildings often do not have electrical technician, with ATS, AMF panels are all made easy, power outages okey, immediately start your own genset, pln flame back ... okay ... stop gensets itself, the technician does not need to run around in a panic just to hurry to start the generator and switches so that the wheels pass undisturbed activity, the most important generator should still be maintained so that the system can work optimally, treating generators as easy as caring for the car, home water batteries are in level, there is enough fuel, normal radiator water, oil ... normal, already .., just like that, for the warm-up generators should look just ats AMF panel that is equipped with automatic heating facilities, generators will perform self-heating in a scheduled without having to turn off the electricity pln, without disturbing the system and wheels office activities, without the need for operators 'impromptu' that scared from the sound generator to heat the generator, everything becomes easier.3. Offers protection against office equipment such as computers, air conditioning, factory and laboratory equipment, there is often an electrical voltage or genset pln suddenly dropped or even sudden rise until well beyond the tolerance limit of normal for the security of electronic tools, there are often even wrong single phase power is lost (for 3 phase systems), and the increasing voltage drop, or loss of voltage is sometimes not detected with the naked eye, suddenly there came the smell of charred burning equipment, well ... Plus a new problem, no air conditioning could have used the paper to the fans, but what must be faced if the damaged is a computer or other media programs, follow-up data might be lost, especially if the problem again ...., which were damaged is the laboratory equipment or equipment that uses plc programming system, the voltage over voltage could damage the tool, it took a long time to fix it, sometimes even forced to pivot for 3-4 months just to wait for the arrival of spare parts or technicians 'import'. Ats with AMF panel this then it can be easy again, over voltage? under voltage? over frequency? under frequency? phase is lost? not a problem, ATS and AMF system that will perform tasks that must be assigned.

Comments

  1. Hey, I found your article Very Informative,PTS APAC Private Limitedis a company that specializes in end-to-end LV and MV switching control gears for organizations worldwide. We manufacture automatic transfer switches that exemplify innovation and uniqueness in terms of design and features.

    ReplyDelete

Post a Comment

Popular posts from this blog

understanding the relationship star - delta

ATS (Automatic Transfer Switch)